Ten: Troubleshooting 75
Providing a brighter solution.™
Section 10:
Troubleshooting
After you have completed installation and programming, make sure the system is working OK by
completing the procedures listed below. Later on, if problems develop in using the system, going
over these same procedures will help you troubleshoot the problem.
This section will help you troubleshoot the following problems:
The system appears to work, the LED’s turn ON and OFF but the power circuits and attached •
equipment will not turn ON.
The 2-speed pump will not operate in 2-Speed mode. •
High speed and low speed circuits turn ON together when the pump is turned ON.•
The circuit breaker for the pump trips every time that the Pump turns ON. •
The heater will not turn ON. •
The heater turns OFF but gets very hot after the pump turns OFF.•
Water or moisture is visible inside the screen of the Hand-Held Controller.•
The Hand-Held Controller appears to be “LOCKED UP”.•
The PE653 Device appears to be ‘LOCKED UP”. •
Problem What to do Reference/Procedure
The system appears to work,
the LED’s turn ON and OFF
but the power circuits and
attached equipment will not
turn ON
Verify that the voltage is
correct at the PE653 power
terminals.
Check the voltage at terminals #1 and #2 on the PE653 1.
using a meter.
Verify that the Voltage Selector is in the correct 2.
position: either 120 V or 240 V depending upon the
voltage observed at terminals #1 and #2.
CAUTION: If a 2-speed pump or other 240 VAC
equipment is being used in the system, the voltage
must be 240 VAC.
NOTE: The PE653 will appear to function correctly,
LED’s will turn ON and it will communicate with the
PE953 Hand Held Controller but the power relays
will turn on when 120 VAC is supplied to a 240 VAC
system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermatic PE653RC Multi Wave and is the answer not in the manual?

Intermatic PE653RC Multi Wave Specifications

General IconGeneral
BrandIntermatic
ModelPE653RC Multi Wave
CategoryControl Systems
LanguageEnglish

Related product manuals