SV-DA200 series AC servo drive Function codes
-123-
fully-closed loop control.
In the previous 1
st
gain, if the position command is not 0, it will switch
to 2
nd
gain.
In the previous 2
nd
gain, if the 0 position command lasts in the delay
time, it will return to 1
st
gain.
In the previous 1
st
gain, if the positioning is not finished, it will switch
to 2
nd
gain.
In the previous 2
nd
gain, if the state of positioning finished lasts in the
delay time, it will return to 1
st
gain.
In the previous 1
st
gain, if the absolute value of the actual speed
exceed (level+delay) [r/min], it will switch to 2
nd
gain.
In the previous 2
nd
gain, if the absolute value of the actual speed
keeps below (level-delay) [r/min] and such state in the delay time, it
will return to 1
st
gain.
With position
command+
actual speed
In the previous 1
st
gain, if the position command is not 0, it will switch
to 2
nd
gain.
In the previous 2
nd
gain, if the 0 position command lasts in the delay
time and the absolute value of actual speed is below (level-delay)
[r/min], it will return to 1
st
gain.
Delay time of position
control switching
In the position control, if set P2.22 to 3–9, when switching from 2
nd
gain to 1
st
gain, it is the time
from meeting the trigger conditions to the actual switching.
Switching level of
position control
In the position control, if set P2.22 to 3–5, 8, 9, it is necessary to set triggering condition of gain
switching. The unit will vary with the switching mode and setting.
Note: Please set the level ≥ the delay
Switching delay of
position control
In the position control, if set P2.22 to 3–5, 8, 9, it is necessary to set switching conditions. The
unit will vary with the switching mode and setting.