SV-DA200 series AC servo drive Control mode applications
-62-
This function is output PTP output 2 signal.
This function is output PTP output 3 signal.
This function is output PTP output 4 signal.
This function is output PTP output 5 signal.
This function is output PTP output 6 signal.
This function is output PTP output 7 signal.
Gantry synchronization output clear
This function is to output the clearance signal of gantry synchronization
Dynamic brake relay control
This function is output dynamic brake relay control signal.
4.4.5 Pulse input signals and functions
Position command
pulse input 1
In the position control mode, act as the position
command input terminal.
In other control mode, the terminal is invalid.
Allowed Max. input pulse frequency: 4MHz in
differential motion mode, 200kHz in open-collector
mode.
Position command
pulse input 2