SV-DA200 series AC servo drive Control mode applications
-55-
This function is the control signal of retention pulse clearing and the detailed operation is relative
to the setting of P3.45.
P3.45=0 means electrical level clear. When the digital input is valid, retention pulse will be 0;
P3.45=1 means rising edge clear. When the digital input triggers retention pulse clearing from the
edge of 0→1, only clear once.
This function is the control signal of stopping receiving the command pulse and the detailed
operation is relative to the setting of P3.44.
P3.44 is 0, the function is valid and when P3.44 is 1, the function is invalid.
This function is the control signal of 1
st
and 2
nd
torque limit switching.
Please refer to the instruction of P0.09.
There are 1–8 signal selections for the internal speed command and 1–4 for the internal speed limit.
Parameters and setting value
This function serves as the control signal of zero speed clamp, refer to P0.58 for detailed
information.