SV-DA200 series AC servo drive Control mode applications
-72-
Control module is NPN type (common cathode):
Control module
side
Drive side
19 OC_EXA
2 EXA-
FG
Y0
EXA
EXB
18 OC_EXB
Shielded cable Twisted pair
4 EXB-Y1
6 EXZ-
Y2
+
-
DC24V
EXZ
17 OC_EXZ
Control module is PNP type (common anode):
Control module
side
Drive side
FG
Y1
Y0
EXA
EXB
+
-
Shielded cable Twisted pair
DC24V
Y2
EXZ
19 OC_EXA
2 EXA-
18 OC_EXB
4 EXB-
6 EXZ-
17 OC_EXZ
Max input pulse frequency is 200kHz; if the local 24V power of DA200 (only 100mA power is
available) or the 24V power provided by the user is used, there is no need to connect current
limit resistor. Generally, PLC of Japanese brands mainly adopts NPN type while PLC under
European brands mainly adopts PNP type.