Name: Basis
12.03.99
Keep on Running Functions
© KEB Antriebstechnik, 1997
All Rights reserved
Functional Description
Chapter Section Page
Date
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
A
B
C
Used Parameters
Pn.4 2204h ✔✔- 0 7 1 - bit-coded
Pn.5 2205h ✔✔- 10 % 199 % (200 = oFF) 1 % 140 % % referring to rated inverter current
Pn.6 2206h ✔✔- 200 V 800 V 1 V 720 / 375 V depending on voltage class
uF.16 2310h -- 0 2 1 1 -
Picture 6.7.1.b Examples for ramp stop function
Actual frequency (ru.3)
Inverter status (ru.0)
Actual load (ru.7)
max. ramp current Pn.5
Acceleration stop
Actual frequency (ru.3)
Inverter status (ru.0)
DC-link voltage (ru.11)
Deceleration stop (U)
max. DC-voltage Pn.6