ANTRIEBSTECHNIK
KEB COMBIVERT F4-C
Name: Basis
4
13
09.02.98
4
OperationFundamentals
© KEB Antriebstechnik, 1997
All Rights reserved
Section
Page
Date
Chapter
4.1.1 Parameters,
Parameter Groups,
Parameter Sets
4.1 Fundamentals
The following chapter describes the fundumentals of the software structure as well
as the operation of the unit.
The control board F4-C incorporates 3 operating modes:
Operating Modes of
Control Board F4-C
Customer Mode
- is a list of parameters
(CP-Parameter), freely
definable, which are
necessary or important
for the user.
- suppllied with a para-
meter list defined by
KEB
Application Mode
- all parameter groups
(exception: CP-
parameter) and
parameter sets can be
selected and, if
necessary, changed
- usually it is activated
only for the adaption to
the application
Drive Mode
- with this special mode,
the unit can be put into
operation via operator
- with the exception of the
control release no
terminal wiring is
needed
What are parameters, parameter groups and parameter sets?
Parameters are values changeable by the operator in a program, which have an
influence on the program flow. A parameter consists of
Parameter designation and Parameter value
Example:
Each parameter is
clearly specified!
The parameter value shows the
actual setting.
The parameter number specifies the parameters
within a group.
To maintain a cleary-to-survey operation inspite of the great
number of parameters, we have combined function-related
parameters into parameter groups (e.g. all motor-related
parameters are combined in the Drive(dr)-group).
8 parameter sets (0...7) exist to adjust several values for one
parameter. If the active values shall be displayed for a running unit
the digit is set to „A“. The digit is not-applicable for non-programmable
parameters.
A conveyor belt shall be used with 3 different speeds. A parameter set is programmed
for each „speed“ ... acceleration, deceleration etc. can be adjusted individually.
4. Operation

Table of Contents

Other manuals for KEB COMBIVERT F4-C