5
ANTRIEBSTECHNIK
6
12 5
KEB COMBIVERT F4-C
Name: Basis
30.01.98
6
Functional DescriptionCP-Parameter Definition
© KEB Antriebstechnik, 1997
All Rights reserved
Chapter
Section
Page
Date
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
6.12.4 Example
For example, a user menu with following characteristics shall be programmed:
1. Display of actual set frequency (ru.3) in the set valid at the time
2. Adjustment of a fixed frequency (oP.22) in set 2
3. Adjustment of a fixed frequency (oP.22) in set 3
4. Acceleration and deceleration time (oP.11/oP.12) in the set active at the time
5. Energy-saving factor (uF.7) shall be adjustable in set 0
6. On switch-on the active parameter set (ru.18) shall be displayed
1.) ud.15 = 2003 ; Parameter address for ru.3
ud.16 = A ; Display in the active set
2.) ud.17 = 2116 ; Parameter address for oP.22
ud.18 = 2 ; Preadjustment in set 2
3.) ud.19 = 2116 ; Parameter address for oP.22
ud.20 = 3 ; Preadjustment in set 3
4.) ud.21 = 210B ; Parameter address for oP.11
ud.22 = A ; Preadjustment in the set active at the time
ud.23 = 210C ; Parameter address for oP.12
ud.24 = A ; Preadjustment in the set active at the time
5.) ud.25 = 2307 ; Parameter address for uF.7
ud.26 = 0 ; Preadjustment in set 0
6. ud.27 = 2012 ; Parameter address for ru.18
ud.28 = A ; Display in the active set
ud.2 = 1 ; Display of ru-parameters (by activating the CP-mode this
setting is ignored)
ud.3 = 7 ; Display of CP.7
adjust all other parameters to „off“ so that no indication occurs
6.12.5 Used Parameters
ud.0 2600h - 0 9999 1 cp_on -
ud.1 2601h - - -32767 32767 1 cp_on only visible by bus
ud.2 2602h - - 1(ru) 13 (LE) 1 ru ru/oP/Pn/uF/dr/cn/ud/Fr/An/di/do/LE/In
ud.3 2603h - - 0 *255 *1 1 * dependent on parameter group
ud.13 260Dh - - - - - - - only visible by bus
ud.14 260Eh - - - - - - - only visible by bus
ud.15 260Fh - - -1 (off) 7FFF 1 2003 corresponds to ru.3
ud.16 2610h - - 0 8 1 0 set 0...7; A(8) = active set

Table of Contents

Other manuals for KEB COMBIVERT F4-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-C and is the answer not in the manual?

KEB COMBIVERT F4-C Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-C
CategoryDC Drives
LanguageEnglish

Related product manuals