Page #86 background imageLoading...
Page #86 background image
6 1
Name: Basis
KEB COMBIVERT F4-C
16
09.04.99
© KEB Antriebstechnik, 1999
All Rights reserved
Functional Description
Chapter Section Page
Date
Operating and Appliance Displays
Adr.
min max
default
Adr.
min max
default
2C01h
0,1
A
LTK
4600
6.1.5 Description of In-Parameters
2C00h
In. 0 Inverter type
1
hex
-
--
The inverter type is indicated in hexadecimal numbers. The bits have following meaning:
bit 0: Voltage class 0 = 200V
1 = 400V
bit 1-5 Unit size 05,07,09,....
bit 6-9 Control type 0 = 0A.F4 ( F4-C / up to housing size E )
1 = 0B.F4 ( F4-S / up to housing size E )
2 = 00.F4 ( F4-C / from housing size G upwards)
bit 10-12 Rated operating frequency 0 = 2kHz
1 = 4kHz
2 = 6kHz
3 = 8kHz
4 = 10kHz
5 = 12kHz
6 = 14kHz
7 = 16kHz
bit 13-15 Maximal operating frequency 0 = 2kHz
1 = 4kHz
2 = 6kHz
3 = 8kHz
4 = 10kHz
5 = 12kHz
6 = 14kHz
7 = 16kHz
Example:
hex F C 9 D
binary 1 1 1 1 1 1 0 0 1 0 0 1 1 1 0 1
decimal 7 7 2 14 1
=> 14.F4.C 16 / 16kHz 400V
In. 1 Rated inverter current
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.

Table of Contents

Other manuals for KEB COMBIVERT F4-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-C and is the answer not in the manual?

KEB COMBIVERT F4-C Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-C
CategoryDC Drives
LanguageEnglish

Related product manuals