EasyManuals Logo
Home>KEB>DC Drives>COMBIVERT F4-C

KEB COMBIVERT F4-C Applications Manual

KEB COMBIVERT F4-C
283 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
5
ANTRIEBSTECHNIK
5
15
KEB COMBIVERT F4-C
Name: Basis
5
Section PageDate
© KEB Antriebstechnik, 1997
All Rights reserved
Chapter
20.03.98
Parameter
5.1.2 Parameter Listing
F4-C
Pr - Parameter Addr.
min
max
default
[?] see page(s)
Pr 4 Pole Number 012A - - 2 12 2 4 - 11.2.4
Pr 5 Malfunction Code 0105 - - - 0 65535 1 - - 11.2.4
Pr 6 Control Word 0106 - - 0 65535 1 0 - 11.2.4; 11.2.8
Pr 7 Status Word 0107 - - - 0 65535 1 - - 11.2.5; 11.2.8
Pr 8 Nominal Speed Value 0108 - - -32767 32767 1 0 rpm 11.2.5; 6.4.5
Pr 9 Actual Speed Value 0109 - - - -32767 32767 1 - rp m 11.2.5
Pr 10 Speed Min. Amount 010A - - 0 32767 1 0 rpm 11.2.5
Pr 11 Speed Max. Amount 010B - - 0 32767 1 1500 rpm 11.2.5
Pr 16 Acceleration Delta Speed 0110 - - 1 32767 1 1500 rpm 11.2.5
Pr 18 Acceleration Delta Time 0112 - - 0 32767 1 10 sec 11.2.6
Pr 25 Deceleration Delta Speed 0119 - - 1 32767 1 1500 rpm 11.2.6
Pr 27 Deceleration Delta Time 011B - - 0 32767 1 10 sec 11.2.6
Pr 37 Speed Control Variable 0125 - - - -32767 32767 1 - rpm 11.2.6; 6.4.5
Pr 38 Set Value Percentage 0126 - - -200 200 0,61 0 % 11.2.6
Pr 39 Percentage Reference Value 0127 - - 0 32767 1 1500 rpm 11.2.7
Pr 40 Actual Percentage 0128 - - - -200 200 0,61 - % 11.2.7
Pr 41 Percentage Control Variable 0129 - - - -200 200 0,61 - % 11.2.7
ru - Parameter Addr.
min
max
default
[?] see page(s)
ru 0 Inverter State 2000 - - - table - - 6.1.5; 6.7.6; 6.12.4
ru 1 Actual Speed Display 2001 - - - 0,5 - rpm 6.1.7; 6.10.9; 6.10.10
ru 3 Actual Frequency Display 2003 - - - -409,5875 409,5875 0,0125 - Hz 6.1.7; 6.7.6
ru 4 Set Speed Display 2004 - - - 0,5 - rpm 6.1.7; 6.4.12
ru 6 Set Frequency Display 2006 - - - -409,5875 409,5875 0,0125 - Hz 6.1.8; 6.4.12
ru 7 Actual Inverter Utilization 2007 - - - 0 200 1 - % 6.1.8; 6.7.6
ru 8 Peak Inverter Utilization 2008 - - 0 200 1 - % 6.1.8
ru 9 Apparent Current 2009 - - - 0,1 - A 6.1.8
ru 10 Active Current 200A - - - 0,1 - A 6.1.8
ru 11 Actual DC Voltage 200B - - - 1 - V 6.1.9
ru 12 Peak DC Voltage 200C - - 1 - V 6.1.9
ru 13 Output Voltage 200D - - - 0 1 - V
ru 14 Input Terminal State 200E - - - table - - 6.1.9; 6.3.3; 6.3.4
ru 15 Output Terminal State 200F - - - table - - 6.1.10; 6.3.13
ru 16 Internal Input State 2010 - - - table - - 6.1.10; 6.3.3; 6.3.8
ru 17 Internal Output State 2011 - - - table - - 6.1.11
ru 18 Actual Parameterset 2012 - - - table - - 6.1.11
ru 22 Ref 1 display 2016 - - - -100,0 100,0 0,1 - % 6.1.11; 6.2.10
ru 23 Ref 2 display 2017 - - - -100,0 100,0 0,1 - % 6.1.11; 6.2.10; 6.4.5
ru 24 OL Counter Display 2018 - - - 0 100 1 - % 6.1.12; 6.4.5
ru 29 Heat Sink Temperature 201D - - - 1 - °C 6.1.12
ru 30 Ext. PI Output Display 201E - - - -100,0 100,0 0,1 - % 6.1.12; 6.4.5; 6.11.5
ru 31 Power On Counter 201F - - 0 65535 1 - h 6.1.12
ru 32 Modulation On Counter 2020 - - 0 65535 1 - h 6.1.12
ru 33 Timer A Act. Value 2021 - - 0 327,67 0,01 0,00 s / h 6.1.13; 6.9.18
ru 34 Motorpoti Act. Value 2022 - -100,00 100,00 0,01 0,00 % 6.1.13; 6.9.14; 6.9.15
ru 41 Analog Out 1 Display 2029 - - - -100,0 100,0 0,1 - % 6.1.13
ru 43 Programmable Display 202B - - - -32767 32767 - - - 6.1.13; 6.9.23
ru 44 Act. Switching Freq. 202C - - - 1 16 1 - kHz 6.1.13; 6.5.6
ru 45 Aanalog Option Display 202D - - - 0,1 - % 6.2.10; 6.10.9
ru 46 Ramp Frequency 202E - - - 0,0125 - Hz 6.4.12
ru 47 Act Encoder Frequency 202F - - - 0,0125 - Hz 6.10.10
oP - Parameter Addr.
min
max
default
[?] see page(s)
oP 0 Reference Source 2100 √√ 0 26 1 1 - 6.4.5; 6.4.6; 6.4.8; 6.9.15
oP 1 Freq. Reference Setting Abs. 2101 - -409,5875 409,5875 0,0125 0,0000 Hz 6.4.5
oP 2 Freq. Reference Setting % 2102 - -100,0 100,0 0,1 0,0 % 6.4.5
oP 3 Rotation Setting 2103 √√ 0 2 1 0 - 6.4.6
oP 4 Min. Freq. Reference Forward 2104 - 0,0000 409,5875 0,0125 0,0000 Hz 4.4.5; 6.4.5; 6.4.9; 6.9.14
oP 5 Max. Freq. Reference Forward 2105 - 0,0000 409,5875 0,0125 70,0000 Hz 6.4.5; 6.4.9
oP 6 Min. Freq. Reference Reverse 2106 - -0,0125 : off 409,5875 0,0125 -0,0125 : off Hz 6.4.5; 6.4.9; 6.9.14
oP 7 Max. Freq. Reference Reverse 2107 - -0,0125 : off 409,5875 0,0125 -0,0125 : off Hz 6.4.5; 6.4.9
oP 8 Abs. Max. Freq. Forward 2108 - 0,0000 409,5875 0,0125 409,5875 Hz 6.4.9
oP 9 Abs. Max. Freq. Reverse 2109 - -0,0125 : off 409,5875 0,0125 -0,0125 : off Hz 6.4.9
oP 10 Acc Dec Mode 210A √√ 0 255 1 0 - 6.4.12; 6.4.16
oP 11 Acceleration Time Forward 210B - 0,00 300,00 0,01 10,00 sec 6.4.13; 6.4.14
oP 12 Deceleration Time Forward 210C - 0,00 300,00 0,01 10,00 sec 6.4.13; 6.4.14
oP 13 Acceleration Time Reverse 210D - -0,01 : off 300,00 0,01 -0,01 : off sec 6.4.13; 6.4.14
oP 14 Deceleration Time Reverse 210E - -0,01 : off 300,00 0,01 -0,01 : off sec 6.4.13; 6.4.14
oP 15 S-Curve Time Acc. Forward 210F - 0 : off 5,00 0,01 0 : off sec 6.4.14
oP 16 S-Curve Time Dec. Forward 2110 - 0 : off 5,00 0,01 0 : off sec 6.4.14
oP 17 S-Curve Time Acc. Reverse 2111 - 0 : off 5,00 0,01 0 : off sec 6.4.14
oP 18 S-Curve Time Dec. Reverse 2112 - 0 : off 5,00 0,01 0 : off sec 6.4.14
oP 22 Step Frequency 1 2116 - -409,5875 409,5875 0,0125 5,0000 Hz 6.4.11
oP 23 Step Frequency 2 2117 - -409,5875 409,5875 0,0125 50,0000 Hz 6.4.11
oP 24 Step Frequency 3 2118 - -409,5875 409,5875 0,0125 70,0000 Hz 6.4.11
oP 25 Step Frequency Mode 2119 √√ 0 3 1 2 - 6.4.11
oP 26 Motorpoti Function 211A - - 0 15 1 8 - 6.1.13; 6.9.14
oP 27 Motorpoti Min. Value 211B - - -100,00 100,00 0,01 0,00 % 6.9.14
oP 28 Motorpoti Max. Value 211C - - -100,00 100,00 0,01 100,00 % 6.9.14; 6.9.15

Table of Contents

Other manuals for KEB COMBIVERT F4-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-C and is the answer not in the manual?

KEB COMBIVERT F4-C Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-C
CategoryDC Drives
LanguageEnglish

Related product manuals