5 1
KEB COMBIVERT F4-C
6
Name: Basis
Chapter
Section Page Date
© KEB Antriebstechnik, 1997
All Rights reserved
20.03.98
Parameter
oP 29 Motorpoti Inc./Dec. Time 211D - - 0,00 300,00 0,01 131,00 sec 6.9.14
oP 30 Motorpoti Prescaler 211E - √√ 0 8 1 0 - 6.9.14
oP 31 Motorpoti Destination 211F - √√ 0 2 1 0 - 6.9.15; 6.11.11
oP 32 Max. Output Freq. Forward 2120 - 0,0000 In. 2 (409,5875) 0,0125 In. 2 (409,5875) Hz 6.11.11
oP 33 Max. Output Freq. Reverse 2121 - -0,0125 : off In. 2 (409,5875) 0,0125 -0,0125 : off Hz
Pn - Parameter Addr.
min
max
default
[?] see page(s)
Pn 0 Auto Restart UP 2200 - - 0 1 1 1 - 6.7.8
Pn 1 Auto Restart UP 2201 - - 0 1 1 0 - 6.7.8
Pn 2 Auto Restart OC 2202 - - 0 1 1 0 - 6.7.8
Pn 3 Motorprotection / Mode 2203 - 0 4 1 0 - 6.7.9
Pn 4 LAD Stop Function 2204 - 0 7 1 1 - 6.7.3
Pn 5 LAD Load Level 2205 - 10 200 : off 1 140 % 6.7.3
Pn 6 LD Voltage 2206 - 200 800 1 720 / 375 (LTK) V 6.7.3
Pn 7 Speed Search Condition 2207 - 0 15 1 8 - 6.7.7; 6.7.8
Pn 8 DC Braking Mode 2208 - 0 9 1 7 - 6.9.3
Pn 9 DC Braking Start Freq. 2209 - 0,0000 409,5875 0,0125 4,0000 Hz 6.9.3
Pn 10 DC Braking Max. Voltage 220A - 0,0 25,5 0,1 25,5 % 6.9.3
Pn 11 DC Braking Time 220B - 0,00 100,00 0,01 10,00 sec 6.9.3
Pn 12 Stall Mode 220C - 0 8 1 1 - 6.7.5; 6.7.6
Pn 13 Stall Level 220D - 10 200 : off 1 200 % 6.3.11; 6.7.6
Pn 14 Stall Acc/Dec Time 220E - 0,00 300,00 0,01 10,00 sec 6.7.5; 6.7.6
Pn 15 Motorprotection / Counter Selection 220F - 0 max. set 1 0 - 6.7.9
Pn 16 E.dOH Delay Time 2210 - - 0 120 1 10 sec 6.3.11; 6.7.10
Pn 17 Power Off Starting Voltage 2211 - - 198 : Off 800 1 198 : Off V 6.9.7; 6.9.8
Pn 18 Power Off Braking Torque 2212 - - 0 : uzk-Mode 100 0,1 0 : uzk-Mode % 6.9.7; 6.9.9
Pn 19 Power Off Restart Frequency 2213 - - 0,0000 409,5875 0,0125 0,0000 Hz 6.9.8; 6.9.10
Pn 33 Power Off Mode 2221 - - 0 63 1 2 - 6.9.8
Pn 34 Power Off KP Uzk 2222 - - 0 2000 1 512 - 6.9.9
Pn 36 Power Off KP Iw 2224 - - 0 2000 1 50 - 6.9.9
Pn 37 Power Off KI Iw 2225 - - 0 2000 1 50 - 6.9.9
Pn 38 Power Off Jump Factor 2226 - - 0 255 1 100 % 6.9.8
Pn 42 Power Off Set Voltage 222A - - 199 : Auto 800 1 199 : Auto V 6.9.7; 6.9.9
Pn 43 Power Off Wait Time 222B - - 0,00 100,00 0,01 0,00 sec 6.9.10
Pn 50 Speed Search Mode 2232 - - 0 127 1 0 - 6.7.7; 6.7.8
Pn 51 Brake Mode 2233 - 0 2 1 0 - 6.9.20
Pn 52 Start Time 1 2234 - 0,00 100,00 0,01 1,00 sec 6.9.19
Pn 53 Start Time 2 2235 - 0,00 100,00 0,01 1,00 sec 6.9.19
Pn 54 Start Frequency 2236 - -50,0000 50,0000 0,0125 2,0000 Hz 6.9.19; 6.9.21
Pn 55 Stop Time 1 2237 - 0,00 100,00 0,01 1,00 sec 6.9.19
Pn 56 Stop Time 2 2238 - 0,00 100,00 0,01 1,00 sec 6.9.19
Pn 57 Stop Frequency 2239 - -50,0000 50,0000 0,0125 2,0000 Hz 6.9.21
Pn 58 Min. Load for Brake Control 223A - 0 100 1 0 % 6.9.19; 6.9.20
Pn 61 Auto Restart E.net 223D - - 011 1-
uF - Parameter Addr.
min
max
default
[?] see page(s)
uF 0 Rated Frequency 2300 - 0,0000 409,5875 0,0125 50,0000 Hz 6.5.3
uF 1 Boost 2301 - 0,0 25,5 0,1 2,0 % 6.5.3
uF 2 Additional Rated Freq. 2302 - 0,0000 409,5875 0,0125 0,0000 Hz 6.5.3
uF 3 Additional Rated Voltage 2303 - 0,0 100,0 0,1 0,0 % 6.5.3
uF 4 Delta Boost 2304 - 0,0 25,5 0,1 0,0 % 6.5.4
uF 5 Delta Boost Time 2305 - 0,00 10,00 0,01 0,00 sec 6.5.4
uF 6 Energy Saving Mode 2306 - 0 7 1 3 - 6.9.5
uF 7 Energy Saving Level 2307 - 0 150 1 70 % 6.9.5
uF 8 DC Voltage Compensation 2308 - 1 650 : off 1 650 : off V 6.5.4
uF 9 Min. Freq. For Modulation 2309 - 0,0000 409,5875 0,0125 0,0000 Hz 6.5.5
uF 10 Modulation Mode 230A - 0 1 1 1 - 6.5.5
uF 11 Carrier Frequency 230B - 1 In. 3 1 LTK kHz 6.5.3; 6.5.6
uF 16 Current Limitation ON/OFF 2310 - - 0 2 1 1 - 6.7.3
uF 17 Transistor on Delay Time Comp. ON/OFF 2311 - - 0 1 / 2 (LTK) 1 1 - 6.7.11
dr - Parameter Addr.
min
max
default
[?] see page(s)
dr 1 Rated Motor Speed 2401 - 0 65535 1 LTK rpm 6.6.3
dr 2 Rated Motor Current 2402 - 0,0 370,0 0,1 LTK A 6.6.3; 6.7.9
dr 3 Rated Motor Frequency 2403 - 0,0000 409,5875 0,0125 50,0000 Hz 6.6.3
dr 4 Rated Motor cos(Phi) 2404 - 0,50 1,00 0,01 LTK - 6.6.3
dr 5 Motor Terminal Resistance 2405 - 0,00 LTK 0,01 LTK Ohm 6.6.4
dr 12 Rated motor voltage 240C - 150 500 1 LTK V 6.6.3
dr 22 Breakdown Factor 2416 - 1,0 4,0 0,1 2,5 - 6.6.3
dr 24 Interface Select 2418 - - 0 7 1 0 - 6.10.7; 6.10.10
dr 25 Encoder 1 (inc/r) 2419 - - 1 10000 1 2500 inc/r 6.10.8
dr 29 Change Encoder 1 Rotation 241D - - 0 1 1 0 - 6.10.9
dr 30 Encoder 2 (inc/r) 241E - - 1 10000 1 2500 inc/r 6.10.8; 6.10.10
dr 34 Change Encoder 2 Rotation 2422 - - 0 1 1 0 - 6.10.9; 6.10.10
dr 35 Gear Ratio Channel 1 2423 - - -20,000 20,000 0,001 1,000 - 6.9.15; 6.10.10
dr 36 Gear Ratio Channel 2 2424 - - -20,000 20,000 0,001 1,000 - 6.9.15; 6.10.9
dr 37 Filter Encoder 1 2425 - - 0 6 1 0 - 6.10.8; 6.10.9
dr 38 Filter Encoder 2 2426 - - 0 6 1 0 - 6.10.8; 6.10.9; 6.10.10
dr 43 Initiator Direction 242B - - 011 0-
dr 44 Reference Speed Tacho Evaluation 242C - - 0 9999 1 1500 rpm 6.10.9
cn - Parameter Addr.
min
max
default
[?] see page(s)
cn 0 Control Mode 2500 - 0 255 1 3 - 6.11.4; 6.11.5
cn 1 Slip Compensation Gain 2501 - -2,50 2,50 0,01 0,00 - 6.11.6
cn 2 Torque Compensation Gain 2502 - -2,50 2,50 0,01 0,00 - 6.11.6
cn 3 Act. Speed Source 2503 - 0 2 1 0 - 6.1.7; 6.10.9; 6.10.10
cn 10 Ext. PI Add Ref Fmin 250A - 0,0000 409,5875 0,0125 10,0000 Hz 6.11.7
cn 11 Ext. PI Add Ref Fmax 250B - 0,0000 409,5875 0,0125 50,0000 Hz 6.11.7
cn 12 Ext. PI Add Ref Source 250C - - 0 3 1 0 - 6.11.7
cn 13 Ext. PI Add Ref Function 250D - 0 3 1 0 - 6.11.7; 6.11.8

Table of Contents

Other manuals for KEB COMBIVERT F4-C