6 12
KEB COMBIVERT F4-C
4
Name: Basis
30.01.98
Functional Description CP-Parameter Definition
© KEB Antriebstechnik, 1997
All Rights reserved
Chapter Section Page
Date
6.12.2 Assignment of
CP-Parameter
The following list shows the assignment of the ud-parameters to the CP-parameters. The
first parameter determines the parameter address (see Chap. 5) of the parameter to be
displayed, the second parameter determines the parameter set in which the values shall be
displayed / changed. Adustable as parameter set is set 0…7 or the active set (A). At „active
set“ the parameter set number is additionally displayed in the 1. digit of the display, to show
which set is actually edited.
= CP.1
= CP.2
= CP.3
= CP.4
= CP.5
= CP.6
= CP.7
= CP.8
= CP.9
= CP.10
= CP.11
= CP.12
ud.15
ud.16
ud.17
ud.18
ud.19
ud.20
ud.21
ud.22
ud.23
ud.24
ud.25
ud.26
ud.27
ud.28
ud.29
ud.30
ud.31
ud.32
ud.33
ud.34
ud.35
ud.36
ud.37
ud.38
= CP.13
= CP.14
= CP.15
= CP.16
= CP.17
= CP.18
= CP.19
= CP.20
= CP.21
= CP.22
= CP.23
= CP.24
ud.39
ud.40
ud.41
ud.42
ud.43
ud.44
ud.45
ud.46
ud.47
ud.48
ud.49
ud.50
ud.51
ud.52
ud.53
ud.54
ud.55
ud.56
ud.57
ud.58
ud.59
ud.60
ud.61
ud.62
6.12.3 Start Parame-
ter (ud.2, ud.3)
The parameter, that is to be displayed after switch-on of the inverter, is selected with the
parameter „Start parameter group“ (ud.2) and „Start parameter number“ (ud.3). For that
the desired parameter group is adjusted in ud.2, the desired parameter number is adjusted
in ud.3. The parameter set is always set 0. If the combination of ud.2 and ud.3 results in a
parameter that does not exist, or if the password level provided at switch-on is not sufficient
to display the parameter, then the inverter starts with the display of ru.0.
If password level < 3 is active at switch-on, i.e. display of the user-defined parameter groups,
then the adjustment of ud.2 is ignored, in that case ud.3 indicates the parameter number of
the CP-parameter, whose value shall be displayed at the start. If this parameter does not
exist, then CP.0 is indicated.

Table of Contents

Other manuals for KEB COMBIVERT F4-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F4-C and is the answer not in the manual?

KEB COMBIVERT F4-C Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F4-C
CategoryDC Drives
LanguageEnglish

Related product manuals