6 9
KEB COMBIVERT F4-C
12
Name: Basis
29.01.98
Name: Basis
Chapter Section Page Date
© KEB Antriebstechnik, 1997
All Rights reserved
Functional Description Special Functions
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
Buffering of short-time Power
Failures
Parameter Setting Remarks
Pn.17 199 (Auto) automatic adaption to starting voltage even at mains
fluctuations
Pn.33 2 (Bit 0 +1) starting voltage = 85 % of DC-link voltage during nor-
mal operation
Pn.41 199 (Auto) setpoint value DC-link voltage = starting voltage
(Pn.17)
Pn.18 0 (Uzk-Mode) DC-link voltage control activated
Emergency Stop with Braking
Module
Parameter Setting Remarks
Pn.17 199 (Auto) automatic adaption of starting voltage even at mains
fluctuations
Pn.33 2 (Bit 0 +1) starting voltage = 85 % of DC-link voltage during nor-
mal operation
Pn.18 100% DC-lnk voltage control deactivated; the drive is
decelerated as quickly as possible
Emergency Stop without
Braking Module
Parameter Setting Remarks
Pn.17 199 (Auto) automatic adaption of starting voltage even at mains
fluctuations
Pn.33 2 (Bit 0 +1) starting voltage = 85 % of DC-link voltage during nor-
mal operation
Pn.18 0 (Uzk-Mode) DC-link voltage control activated
Pn.42 > 199 adjustment of desired setpoint value
Used Parameters
Pn.17 2211h ✔ - - 198, 199, 200 800 V 1 198 (off) 198:off; 199:auto
Pn.18 2212h ✔ - - 0; 0,1 100 % 0,1 0 0: UZK-Mode
Pn.19 2213h ✔ - - 0 409,5875 Hz 0,0125 0 Hz -
Pn.33 2221h ✔ - - 0 127 1 2 bitcodiert
Pn.34 2222h ✔ - - 0 2000 1 512 -
Pn.36 2224h ✔ - - 0 2000 1 50 -
Pn.37 2225h ✔ - - 0 2000 1 50 -
Pn.38 2226h ✔ - - 0 255 % 1 % 100 % -
Pn.42 222Ah ✔ - - 199; 200 800 V 1 199 199: auto
Pn.43 222Bh ✔ - - 0 100,00 s 0,01 s 0 s -