11 2 6
Networks
Bus-/DRIVECOM-Parameter
Chapter
Section
Name:Basis
© KEB Antriebstechnik, 1996
All Rights reserved
Page
Date
26.03.98
KEB COMBIVERT F4-C
Adr.
min max
default
Adr.
min max
default
Adr.
min max
default
Adr.
min max
default
Adr.
min max
default
Pr. 18
Acceleration Delta time
0112h 0 32767 1 10sec
Adjustment of the time that serves for the calculation of acceleration ramp.
Pr. 25
Deceleration Delta speed
0119h 1 32767 1 15001/min
Adjustment of speed change that serves together with Pr.27 for the calculation of the deceleration ramp.
Pr. 27
Deceleration Delta time
011Bh 0 32767 1 10sec
Adjustment of the time that serves for the calculation of the deceleration ramp.
Pr. 37
Speed reference variable
0125h -32767 32767 1 -1/min
Speed at the output of the ramp generator.
Pr. 38
Percent setpoint value
0126h -200 200 0,61 0%
Setpoint setting in percent referred to Pr.39. 16383 ∧ 100% = Pr.39
The setpoint value is calculated according to following formula:
Reference value (Pr.39) · Percentual value(Pr.38)
Setpoint =
100%