.
OPERATION
OPERATION
STOPPING ENGINE
NOTICE
If the engine stops abruptly, service lives of the various parts of the
engine threaten to shorten. Never stop it abruptly except in
emergencies.
In case of overheat of the engine, do not try to stop it abruptly but run
it at medium speeds to cool down gradually, and then stop it.
If the cooling fan does not rotate at the time of overheat, stop the engine.
1.
Run the engine at low idle for approximately 5 minutes to cool
down gradually.
2.
Turn the key of starting switch (1) to the OFF position to stop
the engine.
3. Remove the key from starting switch (1).
CHECK AFTER STOPPING ENGINE
1.
Walk around the machine and check the work equipment, machine exterior, and undercarriage, also check for
any leakage of oil or coolant. If any problems are found, repair them.
2.
Fill the fuel tank.
3.
Check the engine compartment for paper and debris. Clean out any paper and debris to avoid a fire hazard.
4. Remove any mud affixed to the undercarriage.
3 - 106