TRANSMISSION
L3560, L4060, L4760, L5060, L5460, L6060, WSM
3-S3
[2] ERROR DISPLAY ON THE INTELLIPANEL
Error Display for Manual Transmission
Display on IntelliPanel Trouble Item Probable Cause Solution
Reference
Page
ERROR No. 20
CAN NG
Communication error
between ECU and
IntelliPanelâ„¢
• CANbus wiring is disconnected
or short-circuited
• No signals from main ECU for
longer than 5 seconds (error
cleared if signal sent and
received later)
• Main ECU damaged
Check the communication line –
Check the main ECU
connector
9-S38
ERROR No. 30
ECU Memory DEVICE NG
ECU's memory device is
in trouble
• Main ECU memory device
failure
Replace the main ECU 9-S14
ERROR No. 40
Input Voltage NG
Input voltage to sensor
from ECU is in trouble
• Power source (5 V) from
terminal A8 of main ECU is
dropped below 2.6 V for 0.1
second or more
• Wiring for sensor is
short-circuited
Check the output voltage at
main ECU connector
9-S39
Check the sensor connector 9-S48
Check the ground cable 9-S35
ERROR No. 51
Shuttle SWITCH NG
Shuttle lever switch is in
trouble
• Shuttle switch failure Check the shuttle switch 9-S63
Replace the shuttle switch 9-S63
ERROR No. 93
Starter RELAY NG
Starter relay is in trouble
• Starter relay failure
• Wiring for starter relay is
disconnected or short-circuited
Engine does not start –
Replace the starter relay 9-S66
Check the wiring connector of
starter relay
–
ERROR No. 94
OPC NG
OPC is in trouble
• Wiring for OPC is disconnected
or short-circuited
Engine is stopped –
Check the wiring connector of
OPC
9-S62
Check the communication line
between terminal B18 of main
ECU and terminal 20 of
engine ECU
–
ERROR No. 95
PTO SOLENOID NG
Solenoid (PTO) is in
trouble
• PTO solenoid valve failure
• Wiring for PTO solenoid valve
is disconnected or
short-circuited
• Grounding plate of solenoid is
poor contact with chassis
PTO does not rotate –
Check the PTO solenoid valve 3-S20
Replace the PTO solenoid
valve
3-S66
Check the wiring connector of
PTO solenoid valve
–
KiSC issued 03, 2016 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota WSM L6060 and is the answer not in the manual?

Kubota WSM L6060 Specifications

General IconGeneral
BrandKubota
ModelWSM L6060
CategoryTractor
LanguageEnglish

Related product manuals