U052 Setting the fuser motor control
Description
Enters the sensor data values described on the supplied sheet provided when the loop sensor is
replaced and performs correction processing for the fuser motor.
Purpose
To perform when replacing the loop sensor or paper conveying unit.
Method
1. Press the OK key.
2. Select the item.
Method: [Set Loop Sensor]
1. Select [Scanning Board1].
2. Enter the sensor data value of supplied sheet DATA1 using
the numeric keys.
3. Select [Scanning Board2].
4. Enter the sensor data value of supplied sheet DATA2 using
the numeric keys.
5. Press the OK key. The value is set.
Setting: [Loop Sensor Control]
1. Select the item.
2. Change the setting value using the numeric keys.
3. Press the OK key. The setting is set.
Item No. Description
Display Description
Set Loop S Enter the data value for loop sensor
Adj Loop S Perform the adjustment of the loop sensor sensitivity
Loop S Control Set the loop sensor detection control
Set Loop S Valid Sets the presence or absence of the loop sensor
Chk Loop S Display the data value for loop sensor
1(e.g.)
How to read the sensor data value
2
3
4
5
6
7
8
9
0
364
Display Description
ScanBoard1 Scanning Board1 adjustment
ScanBoard2 Scanning Board2 adjustment