2MN/2N1-1
1-3-65
U118 Displaying the drum history
Description
Displays the past record of machine number and the drum counter.
Purpose
To check the count value of machine number and the drum counter.
Method
1. Press the OK key.
2. Select the color to check.
3. Press the OK key.
The history of a machine number and a drum counter for each color is displayed by three
cases.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
U119 Setting the drum
Description
Sets drum sensitivity.
Purpose
To set the drum after replacing the drum unit or laser scanner unit.
When completed, perform maintenance mode U464, Calibration.
Method
1. Press the OK key.
2. Select [Execute].
3. Press the OK key. Drum setup is commenced.
4. Exit the maintenance mode, perform shut-down, and turn the main power switch to off and on
again. Allow more than 5 seconds between Off and On.
Item No. Description
Display Description
C Cyan drum past record
M Magenta drum past record
Y Yellow drum past record
K Black drum past record
Display Description
Machine History1 - 3 Historical records of the machine number
Cnt History1 - 3 Historical records of drum counter