2MN/2N1-1
1-3-60
U107 Setting the transfer cleaning voltage
Description
Sets the cleaning control voltage for transfer belt unit.
Purpose
Change settings if an offset has occurred due to the failure of cleaning the transfer belt.
Method
1. Press the OK key.
2. Select the item to be set.
3. Select the item to be set.
4. Change the value using the numeric keys.
[Belt(A)]
[Belt(B)]
*: 55 ppm model only.
5. Press the OK key. The value is set.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Belt(A) Transfer belt cleaning voltage (printing)
Belt(B) Transfer belt cleaning voltage (paper interval)
Display Description
Setting
range
Initial setting
45ppm 55ppm
Full Full speed 0 to 255 202 207
Half Half speed 0 to 255 180 182
3/4 3/4 times of line speed 0 to 255 192 192
B/W* Black/white mode 0 to 255 - 212
Display Description
Setting
range
Initial setting
45ppm 55ppm
Full Full speed 0 to 255 150 160
Half Half speed 0 to 255 110 110
3/4 3/4 times of line speed 0 to 255 130 130
B/W* Black/white mode 0 to 255 - 160