v Latest level of DSA
v Latest level of BMC/IMM
218-905-000 Brocade:SerdesEthLoopbackTest Failed
Explanation: A failure was detected during the
Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-906-000 Brocade:InternalLoopbackTest Failed
Explanation: A failure was detected during the
Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM
technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
DSA checkpoint panel test results
The following messages can result when you run the checkpoint panel test.
180-000-000 Check-point Panel Test Passed
Explanation: Check-point Panel Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
180-801-000 Check-point Panel Test Aborted
Explanation: Check-point Panel Test Aborted. BMC is
unable to verify that the operator information panel
cable is connected.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Inspect and reseat operator information panel cable
at both ends.
2. Verify that the Baseboard Management Controller
(BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
180-901-000 Check-point Panel Test Failed
Explanation: Check-point Panel Test Failed. Operator
reported incorrect display.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check the operator information panel cabling for
loose or broken connections at both ends or damage
to the cable.
2. Replace the information panel cable if damage is
present.
3. Run the test again.
218-905-000 180-901-000
538
System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenovo x3550 M4 and is the answer not in the manual?

Lenovo x3550 M4 Specifications

General IconGeneral
BrandLenovo
Modelx3550 M4
CategoryServer
LanguageEnglish

Related product manuals