4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
DSA LSI hard drive test results
The following messages can result when you run the LSI hard drive test.
407-000-000 LSIESG:DiskDefaultDiagnostic Test
Passed
Explanation: The test passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
407-800-000 LSIESG:DiskDefaultDiagnostic Test
Aborted
Explanation: The test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
407-900-000 LSIESG:DiskDefaultDiagnostic Test
Failed
Explanation: The hard drive self-test detected a
failure.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your IBM
technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
DSA Mellanox adapter test results
The following messages can result when you run the Mellanox adapter test.
408-000-000 MLNX:MLNX_DiagnosticTestEthernetPort
Test Passed
Explanation: Port Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
408-001-000 MLNX:MLNX_DiagnosticTestIBPort Test
Passed
Explanation: Port Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
407-000-000 408-001-000
546
System x3550 M4 Type 7914: Installation and Service Guide