Function block library
7-164

SHB9300CRV EN 2.0
7.6.52 Conditioning of the setpoint speed (NSET)
Purpose
This FB conditions the
l
main setpoint speed and
l
and additional setpoint (or other signals)
for the subsequent control structure via ramp generator or fixed speeds.
C 0134
C 0182
CINH
*-1
C 0039/1
C 0039/15
C 0039/2
C 0103/1
C 0103/15
C 0103/2
C 0101/1
C 0101/15
C 0101/2
C 0012
C 0013
+
-
*
/
x/(1-y)
*-1
C 0190
x
y
CINH
C 0220/
C 0221
NSET
C 0046
C 0049
NSET-NADD
NSET-N
1
0
1
0
DMUX
0
3
0
15
NSET-NADD-INV
NSET-JOG*1
NSET-JOG*2
NSET-JOG*4
NSET-JOG*8
DMUX
0
3
0
15
NSET-TI*1
NSET-TI*2
NSET-TI*4
NSET-TI*8
J O G 1 ...1 5
TI 0...15
N S E T -N -IN V
N S E T -R F G -S T O P
N S E T -R F G -0
C 0241
NSET-NOUT
N S E T -R F G -I= 0
NSET-SET
NSET-LO AD
NSET-CINH-VAL
C 0799/1
C 0799/12
C 0799/13
C 0798/1
C 0798/2
C 0799/2
C 0799/3
C 0784
C 0790
C 0789
C 0781
C 0780
C 0787/1
C 0788/1
C 0785
C 0786
C 0783
C 0782
C 0787/2
C 0787/3
C 0787/4
C 0788/2
C 0788/3
C 0788/4
C 0130
C 0045
±199,99%
Fig. 7-126 Conditioning of the setpoint speed (NSET)