Configuration
7-261

SHB9300CRV EN 2.0
7.7.3.13 Dig-Set monitoring Sd3
Purpose
Monitors the process.
MONIT
MONIT-SD3
4V
X10
Fig. 7-206 Dig-Set monitoring Sd3
Signal
Source Note
Name Type DIS DIS format CFG List Possibili
ties
X10 - - - - - - -
MONIT-SD3 d - - - - - -
Function
The monitoring Sd3 will be activated if the dig. frequency input X9 of pin 8 is not voltage supplied.
It indicates an interruption of the dig. frequency connection.
Features:
l
LECOM No.: 83, 2083
l
Reaction: TRIP, WARNING or OFF