9.2 Opcal device idencaon
For applicaons including several controllers it may be dicult to locate a device that has
been connected online. The "Opcal device idencaon" funcon serves to locate the
controllerby means of blinking LEDs.
Details
In order to start the visual tracking, set 0x2021:001 = "Start [1]".
Aer the start, both LEDs "RDY" and "ERR" on the front of the controller synchronously blink
very fast.
"RDY" LED (blue) "ERR" LED (red) Status/meaning
Both LEDs are blinking in a very rapidly
synchronous mode
"Visual tracking" funcon is acve.
The blinking rate can be set in 0x2021:002.
Parameter
Address Name / seng range / [default seng] Informaon
0x2021:001 Opcal tracking: Start detecon 1 = start opcal device idencaon.
Aer the start, the two LEDs "RDY" and "ERR" on the front of the
controller are blinking with a blinking frequency of 20 Hz for the
blinking duraon set in 0x2021:002. The seng is then automacally
reset to "0" again.
If the funcon is reacvated within the blinking me set, the me is
extended correspondingly.
A manual reset to "0" makes it possible to stop the funcon
prematurely.
0 Stop
1 Start
0x2021:002 Opcal tracking: Blinking duraon
0 ... [5] ... 6000 s
Seng of the blinking duraon for the visual tracking.
Device funcons
Opcal device idencaon
81

Table of Contents

Other manuals for Lenze C 750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze C 750 and is the answer not in the manual?

Lenze C 750 Specifications

General IconGeneral
BrandLenze
ModelC 750
CategoryController
LanguageEnglish

Related product manuals