Address Name / seng range / [default seng] Informaon
0x231F:002 Communicaon module ID: Module ID connected
Read only
Display of the network opons currently available in the device.
Note!
When switched on, the device checks whether the parameter sengs
saved in the memory module match the device hardware and rmware.
In case of an incompability, a corresponding is error message is output.
48 No network
65 AS-Interface
67 CANopen
71 EtherNet/IP
72 BACnet
78 POWERLINK
80 PROFIBUS
82 PROFINET The controller currently supports these network opons.
84 EtherCAT
86 Modbus TCP/IP
87 Modbus
11.3.3 Service life diagnoscs
Current values on the operang me and temperatures of the controller can be read out.
Parameter
Address Name / seng range / [default seng] Informaon
0x2D81:001 Life-diagnosis: Operang me
Read only: x s
Display showing for how long the device has been running so far. The
counter cannot be reset.
0x2D81:002 Life-diagnosis: Power-on me
Read only: x s
Display showing for how long the device has been supplied with line
voltage so far.
0x2D81:004 Life-diagnosis: Main switching cycles
Read only
Display of the number of switching cycles of the mains voltage.
11.4 Error handling
Error messages can be reset.
Parameter
Address Name / seng range / [default seng] Informaon
0x2841 Reset error
0 ... [0] ... 1
1 ≡ reset error (error acknowledgement)
Diagnoscs and fault eliminaon
Error handling
Service life diagnoscs
97

Table of Contents

Other manuals for Lenze C 750

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze C 750 and is the answer not in the manual?

Lenze C 750 Specifications

General IconGeneral
BrandLenze
ModelC 750
CategoryController
LanguageEnglish

Related product manuals