Operating elements for crane operation
8.2 Brief description of the operating elements
Operating Instructions GMK5250L 3 302 633 en 8 - 127
27.09.2017
8.2.23 Rated capacity limiter (RCL)
CCS display In the Start menu
For the
Standard slewing range type
Only one slewing range is displayed
The displays for working radius, current slew-
ing angle and current position are identical to
the displays for the
MAXbase slewing range
type.
For the
MAXbase slewing range type
– Slewing ranges/working radii display
Represents the defined slewing ranges and
corresponding respective maximum per-
missible operating radii
5
for the confirmed
rigging mode as a diagram.
– Display of current slewing range divisions
Shows the currently defined slewing
ranges
1
to
4
as pillars
1
to
4
. The pillar
width represents the angular range.
– Display of current slewing range limits
Shows the currently defined slewing range
limits (6) in degrees.
For example -35° / +35° / +145° / -145°.
s
1 360° slewing range
2 Restricted slewing range, e.g. ±30°
3 Working position, e.g. 0° to the rear

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals