Operating elements for crane operation
8.2 Brief description of the operating elements
8 - 104 3 302 633 en Operating Instructions GMK5250L
27.09.2017
8.2.12 Outrigger pressure displays
à Outrigger pressure display, p. 11 - 65
Outrigger pressure display
– Unit of measurement
Displayed depending on setting
– t – tons or
– klbs – kilopounds – (1 kilopound =
1,000 lbs)
–Precision
When in t, one decimal place
When in klbs no decimal places
8.2.13 Anemometer display
The anemometer is electrically connected.
v
max
= maximum permissible/reduced wind speed as shown in the
Lifting capacity table
A In the Outrigger menu
B In the Monitoring menu
C On the outrigger control units
1 Display in metres per second (m/sec) or Beaufort scale (B)
2 Variable measurement range – 100% = v
max
– Green: Display (1) ≤ 90% of v
max
–Red: Display (1) > 90% of v
max
à p. 10 - 74