EasyManuals Logo
Home>Manitowoc>Construction Equipment>Grove GMK 5250L

Manitowoc Grove GMK 5250L User Manual

Manitowoc Grove GMK 5250L
958 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #875 background imageLoading...
Page #875 background image
Malfunctions during crane operation
14.3 Warning and error messages
Operating Instructions GMK5250L 3 302 633 en 14 - 7
27.09.2017
14.3.2 Error messages on the CCS Display
•
Stop all crane movements and bring both control levers into the initial
position.
The symbol (1) or (2) flashes when the CCS
has detected an error. The symbols flash
alternately when both error types are present.
(1) – Engine error
• Switch off the engine immediately.
• Open the Engine/transmission error menu (3).
For the subsequent procedure;
à p. 7 - 15.
(2) – Crane operation error
The buzzer tone sounds once.
• Open the Crane operation error menu (4).
Display of error / total errors
Display (2) shows the error total, and
display (1) shows which error is displayed.
3/5, for example, means:
– The error 3 is shown,
– there is a total of 5 errors.
Displaying errors
• Select and acknowledge the symbol (3)
or (4) to show any additional errors.
s
G
Risk of accidents!
Immediately stop operating the crane if an error message is displayed!
The crane control may only be repaired by properly qualified personnel.
3 Next error
4 Previous error

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals