3-87
RT9150E OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
Published 2-23-2017, Control # 644-00
Item Description Graphic Explanation
1
Current telescope
status display
Telescope status of all telescopic
sections in percent, locking pins (1):
•Green: Fixed length, locked with
the locking pin notch engaged to
the section
• Flashing: Intermediate length,
locked, locking pin notch not
engaged to the section
• Black: Intermediate length, not
locked
Refer to Telescoping the Boom, page
3-132.
2 Error display
(1) Error
(2) Warning
(3) Information
(4) Corresponding number code, press
the button once, next available
number code.
Refer to Error Submenu, page 3-101.
3 RCL code display RCL code, four digits.
4 Reeving display
(1) Required quantity of reeved ropes
for displayed, maximum load (2).
5
Maximum load
display
The display (2) shows the maximum
load that can be lifted in the current
rigging mode with the current working
radius.
If the maximum load is reduced due to
the entered reeving, the symbol (1) is
red.
In this case, you can have the
maximum possible load displayed
briefly.
Press the F4 button (3) once.
The display (2) shows the maximum
possible load that can be lifted with
sufficient reeving according to the
Load Chart.
Reference Only