Disconnecting the Hydraulic Connection
1. Remove the hose lines (2) from the connections (1)
(Figure 4-53).
2. Close off the hose lines and the connections (1) with the
protective caps.
3. Secure hoses in holder (1) on the 11 m (36 ft) extension.
Folding Deflection Sheaves
Deploying the Rear Deflection Sheave
1. Remove the retaining clip from the pin (2) (Figure 4-54).
2. Hold the deflection sheave by the handle (1) and pull out
the pin (2).
3. Fold the deflection sheave (3) up and fasten it in this
position with the pin (2).
4. Secure the pin (2) using the retaining clip.
Stowing Rear Deflection Sheave
1. Remove the retaining clip from the pin (2) (Figure 4-54).
2. Hold the deflection sheave by the handle(1) and pull out
the pin (2).
3. Fold the deflection sheave (3) down and fasten it in
position with the pin (2).
4. Secure the pin (2) using the retaining clip.
CAUTION
Pinch Hazard!
Always hold the deflection sheave by the handle when
removing the pin. You might get your fingers crushed if
you hold the sheave by the side plates.