OPERATING CONTROLS AND PROCEDURES RT9150E OPERATOR MANUAL
3-104
Published 2-23-2017, Control # 644-00
5026
Current load is greater than the lift
capacity, lower boom extension
function is disabled
1. Raise the boom extension
2. Press Enter button once
3. If necessary, increase the working radius by lowering
the main boom.
5044
Maximum permissible swing angle
exceeded
Swing into a permissible working range.
5 05 5 Minimum load value not reached
When the main boom is set down, raise main boom and
acknowledge the error. Notify Crane Care if the error
cannot be acknowledged.
6 02 1 Fuse F1 blown
Replace blown fuse; refer to the Service Manual.
6 02 2 Fuse F2 blown
6 02 3 Fuse F3 blown
6 02 4 Fuse F11 blown
6 02 5 Fuse F12 blown
8 01 1 Rigging state not yet confirmed
Confirming the rigging mode, Refer to Entering the
Rigging Mode, page 3-81.
8 02 2 RCL is overridden Cancel the override; Refer to RCL Override, page 3-73.
8033
Swing gear switched ON with RCL
code for working position 0°, 180° or
Free-on-wheels.
Switch off the swing gear.
8141
Maximum permissible overall height
exceeded
1
.
Retract or lower.
8142
Maximum permissible overall working
radius exceeded
1
.
Raise or retract.
8143
Maximum permissible overall swing
range exceeded
1
.
Swing into a permissible working range.
8144
Shutdown area of a monitored object
reached
1
.
Move into a permissible working range.
1
With working range limiter switched on.
Table 3-1Error Code Table
Error code Cause Remedy
Reference Only