Setting from the parameter unit, operation panel
4
PARAMETERS
4.22 Setting from the parameter unit, operation panel
4.22.1 PU display language selection (Pr. 145)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 156.)
4.22.2 Operation panel frequency setting/key lock operation selection (Pr. 161)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 156.)
Purpose Parameter that must be Set
Refer to
Page
Switch the display language of the
parameter unit
PU display language
selection
Pr. 145 223
Use the setting dial of the operation
panel like a volume for frequency
setting.
Key lock of operation panel
Operation panel operation
selection
Pr. 161 223
Control of the parameter unit, operation
panel buzzer
PU buzzer control Pr. 990 225
Adjust the LCD contrast of the parameter
unit
PU contrast adjustment Pr. 991 225
You can switch the display language of the parameter unit (FR-PU04/FR-PU07) to another.
Parameter
Number
Name Initial Value Setting Range Definition
145 PU display language selection 0
0 Japanese
1 English
2Germany
3 French
4Spanish
5Italian
6 Swedish
7Finnish
The setting dial of the operation panel (FR-DU07) can be used like a volume to perform operation.
The key operation of the operation panel can be disabled.
Parameter
Number
Name Initial Value
Setting
Range
Description
161
Frequency setting/key lock
operation selection
0
0
Setting dial frequency
setting mode
Key lock
mode invalid
1 Setting dial volume mode
10
Setting dial frequency
setting mode
Key lock
mode valid
11 Setting dial volume mode