4 - 33 4 - 33
MELSEC-Q
4 SEQUENCE PROGRAM CONFIGURATION AND EXECUTION
CONDITIONS
(e) When the interrupt program/fixed scan execution type program is executed
at a measuring time such as the scan time or execution time, the values of
the interrupt program/fix scan execution type program are added to the
measured time.
Thus, if the interrupt program/ fixed scan execution type program is
executed, the values stored in the following special registers and
GX Developer monitor values will become longer than when the interrupt
program/ fixed scan execution type program is not executed.
1) Special registers
• SD520, SD521: Current scan time
• SD522, SD523: Initial scan time
• SD524, SD525: Minimum scan time
• SD526, SD527: Maximum scan time
• SD528, SD529: Current scan time for low speed
• SD532, SD533: Minimum scan time for low speed
• SD534, SD535: Maximum scan time for low speed
• SD540, SD541: END processing time
• SD542, SD543: Constant scan wait time
• SD544, SD545: Cumulative execution time for low speed execution
type programs
• SD546, SD547: Low speed execution time
• SD548, SD549: Scan program execution time
• SD551, SD552: Service interval time
2) GX Developer monitor values
• Execution time measurement
• Scan time measurement
• Constant scan

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi QCPU (Q Mode) and is the answer not in the manual?

Mitsubishi QCPU (Q Mode) Specifications

General IconGeneral
BrandMitsubishi
ModelQCPU (Q Mode)
CategoryController
LanguageEnglish

Related product manuals