Page #223 background imageLoading...
Page #223 background image
223
GS716T and GS724T Gigabit Smart Switches
To create an IPv6 ACL:
1. To add an ACL, type a name in the IPv6 ACL field, and then click Add.
2. To delete an ACL, select the check box associated with the ACL, and then click Delete.
3. Click Cancel to cancel the configuration on the screen and reset the data on the screen to
the latest value of the switch.
4. If you modify the IPv6 ACL name, click Apply to submit the changes to the switch.
IPv6 Rules
Use the IPv6 Rules page to configure the rules for the IPv6 Access Control Lists. The IPv6
Access Control Lists are created using the IPv6 Access Control List Configuration page. By
default, no specific value is in effect for any of the IPv6 ACL rules.
To display the IPv6 Rules page, click Security
ACL > Advanced IPv6 Rules. In the
following figure, an IPv6 rule exists, and one rule has been configured.

Table of Contents

Other manuals for NETGEAR GS716T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR GS716T and is the answer not in the manual?

NETGEAR GS716T Specifications

General IconGeneral
Switch typeManaged
Switch layerL3
Quality of Service (QoS) supportYes
Stackable-
CertificationCE, FCC, VCCI, EN, C-Tick, CCC, CSA, UL/cUL, IEC
Product colorBlue
LED indicatorsActivity, Link, Power
SFP module slots quantity2
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)
Basic switching RJ-45 Ethernet ports quantity16
Number of VLANs256
Networking standardsIEEE 802.1D, IEEE 802.1as, IEEE 802.1s, IEEE 802.1v, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Copper ethernet cabling technology10BASE-T, 100BASE-TX, 100BASE-T, 1000BASE-T
Noise level0 dB
Mean time between failures (MTBF)567680 h
DHCP featuresDHCP client
Security algorithms802.1x RADIUS, HTTPS, SSL/TLS
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Power consumption (typical)14.4 W
MAC address table16000 entries
Number of static routes32
Operating altitude0 - 3000 m
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)0 - 90 %
Cables includedAC
Supported network protocolsIP
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width440 mm
Height43 mm
Weight2570 g