8.3.2 Updateprocedure
Important:
• ThelesystemofUSBdeviceshouldbeformattedintheFATorFAT32format.Becareful
since the devices formatted in NTFS or other format will not be able to be operated. The
file system can be confirmed on the device properties in applications such as Explorer of
Windows.
• Nevershutdowntheequipmentduringtheupdate.Firmwaredataandthefollowingoption
data (if installed) could be damaged and may not be able to be operated properly.
- Data Overwrite Enabler (GP-1070)
- Meta Scan Enabler (GS-1010)
- External Interface Enabler (GS-1020)
- IPSecEnabler(GP-1080)
- Unicode Font Enabler (GS-1007)
[A] Update procedure
(1) Connect the USB device to the PC and write the model specific folder in which the
data file is stored.
Store the data file for updating in the model specific folder.
(2) Pressthe[ON/OFF]buttononthecontrolpaneltoshutdowntheequipment.
(3) Connect the USB device [1] to the USB port [2] on the right upper cover.
[2]
[1]
Fig.8-10
(4) Press the [ON/OFF] button while simultaneously holding down the [4] and [9] buttons.
Data in the USB device are checked and the checking status is displayed on the
screen.