4-1 Troubleshooting
4-1-2 FINS Command and System File Error Messages
94
Message Probable cause Countermeasure
Cannot open I/O comment
file.
Cannot open I/O comment file
folder.
This message is showed when I/O
comment file is not set or the I/O
comment file cannot be read
because of a Memory Card error.
I/O comment file does not exist.
An I/O comment file does not exist
when setting I/O comment file.
Check if the Memory Card can be read
normally in a computer. Also, check if an I/O
comment file is stored in a Memory Card. If the
specified I/O comment file is not in the
Memory Card, copy the file to the ldrdata
folder of Memory Card.
Cannot open System
initialization file.
Ladder Monitor System
Initialization file (plcon.ini) does
not exist or the System
Initialization file cannot be
accessed because the Memory
Card is corrupted.
Check if the Memory Card can be read
normally in a computer. Check if there is a
System Initialization file. If not, copy the
System Initialization file from the CD-ROM to
the ldnmt folder in the Memory Card. If the
System Initialization file is read-only, set it to
read/write.
Error detected among system
processes. Do you want to exit
the application?
Process error becomes an error
on the Ladder Monitor system.
Exit the Ladder Monitor and restart the PT.

Table of Contents

Other manuals for Omron ns series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron ns series and is the answer not in the manual?

Omron ns series Specifications

General IconGeneral
BrandOmron
Modelns series
CategoryTouch terminals
LanguageEnglish

Related product manuals