Outline of Key Operations Section 2-2
21
2-2 Outline of Key Operations
Note 1. Refer to 2-5-1 RUN Mode Displays for details.
2. Refer to 2-5-3 FUN Mode Displays for function details.
3. The DOWN Key is also used to input the reference incident level set-
ting when a Through-beam Sensor Head is used.
Mode: RUN
Display selection
See note 1.
Timing input
Reset input
Zero reset
Threshold value
Manual setting
Mode: T
Numeric value
Digit position
Threshold value
confirmation/Teaching
See note 3.
Function/numeric
value confirmation
Function selection
See note 2.
Function setting
Mode: FUN
See note 2.
Z157-E1-01C.book Page 21 Thursday, August 31, 2006 5:13 PM