Oracle Database Appliance X3-2/X4-2 Status Indicators
Chapter1 • Overview of System Status Indicators and LEDs 31
Callout Indicator/LED: Color State Meaning
■ Off – Normal operation.
2 Power supply status indicator:
green
■ On – The power supply is operating normally.
■ Off – The power supply is unplugged or turned off.
3 Fan fail indicator: amber ■ On – The fan is faulty.
■ Off – Normal operation.
4 DC power fail indicator: amber ■ On – The power supply is faulty.
■ Off – Normal operation.
5 SAS I/O Module status
indicators: green or amber
■ OK – Lights green to indicate normal operation.
■ Service Required – Lights amber to indicate a fault with the I/O
module (top module is 0; bottom module is 1).
6 Reserved This port is reserved for Oracle Service.
7 Network port (reserved) This port is reserved for Oracle Service.
8 Host SAS port activity indicators
(x4 per port): green
■ Random blinking – Indicates host SAS link activity.
■ Off – No link activity.
Oracle Database Appliance X3-2/X4-2 Status Indicators
This section describes the status indicators for Oracle Database Appliance X3-2 and Oracle
Database Appliance X4-2.
■
“Oracle Database Appliance X3-2/X4-2 Server Node Status Indicators” on page 31
■
“Oracle Database Appliance X3-2/X4-2 Storage Shelf Status Indicators” on page 35
Oracle Database Appliance X3-2/X4-2 Server Node
Status Indicators
This topic describes Oracle Database Appliance X3-2 and Oracle Database Appliance X4-2
server node status indicators (LEDs).
Server Node Front Panel Status Indicators
The Oracle Database Appliance X3-2/X4-2 server node front panel includes indicators for the