Oracle Database Appliance Version 1 Status Indicators
40 Oracle Database Appliance Service Manual • June 2017
Server Node Fan Indicators
Each fan module for Oracle Database Appliance Version 1 has a single bi-colored LED
indicating both fan OK and fan fault conditions. The LED lights green to indicate that the fan
module is properly plugged into the system and operating within the expected RPM range for a
given power management setting. The LED lights amber to indicate a fan fault.
Note - The LEDs on the fan modules are not lit amber on initial system power-on. The fan
amber LED only lights if Oracle ILOM detects a failure that indicates a faulty fan module or a
missing fan that should be installed.
Indicator/LED: Color State Meaning
OK: green Steady on – The fan is functioning normally.
Off – Chassis 3.3V_Standby power is off or there is a fan fault.
Service Required: amber Off – Normal operation.
Steady on – A fault has been detected with the fan.

Table of Contents

Other manuals for Oracle Database Appliance X6-2-HA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle Database Appliance X6-2-HA and is the answer not in the manual?

Oracle Database Appliance X6-2-HA Specifications

General IconGeneral
BrandOracle
ModelDatabase Appliance X6-2-HA
CategoryStorage
LanguageEnglish

Related product manuals