The SoundStructure VoIP Interface
12 - 33
The DHCP boot server settings are only accessible when the DHCP client is
enabled. The Boot server parameters are described in the following table.
Name Possible Values Description
Boot server Static (default) The SoundStructure VoIP Interface will use the boot
server/provisioning server configured manually through
the Server options.
Custom The SoundStructure VoIP Interface will look for the
option number specified by the boot server option
parameter and the type specified by the boot server
option type in the response received from the DHCP
server.
If the DHCP server sends nothing, the following
scenarios are possible:
• If a boot server value is stored in flash memory and
the value is not 0.0.0.0, then the value stored in
flash is used.
• Otherwise the SoundStructure VoIP Interface sends
out a DHCP INFORM query.
If a single alternate DHCP server responds, this is
functionally equivalent to the scenario where the
primary DHCP server responds with a valid boot
server value.
If no alternate DHCP server responds, the INFORM
query process will retry and eventually time out.

Table of Contents

Other manuals for Polycom SoundStructure C16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C16 and is the answer not in the manual?

Polycom SoundStructure C16 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C16
CategoryConference System
LanguageEnglish

Related product manuals