- 36 -
When logged, add users and set the permissions levels (for the procedure of assigning
permissions levels read section 23).
On future Logging In, select a user from the list and enter the password, the software initiates
operation with permissions level set for the selected user.
Log out operation procedure:
Run home screen and press < > button, operators database window opens,
Press <Log out> soft key (located as position no. 1 in the list of operators),
Home screen of the software is displayed again automatically.
Permissions levels
Balance software comprises three permissions levels: administrator, advanced operator, user.
Permissions level dependent access to edition of user parameters, databases and software
functions.
Permissions levels Enabled operations
User
Free editing of parameters of <Readout> submenu. Modification of
settings for <Misc.> parameter group, except for settings for <Date and
Time>.
The operator can start and carry out all weighing processes.
The operator can preview information recorded in <Databases>, (s)he
can define universal variables.
Advanced User
Free editing of parameters of the following submenus: <Readout>;
<Working modes>; <Communication>; <Peripherals>; <Misc.>.
Access to <Date and Time> submenu denied.
The advanced operator can start and carry out all weighing processes.
Administrator
Access to all user parameters and functions, editing databases
enabled.
8.3. UNITS
UNITS parameter group enables you to change availability of mass units (the change can be
performed in-course of balance operation), and to define two custom units, thus positively effecting
comfort and speed of operation. It is possible to change unit to other than unit [g] during weighing
process or during operation of other modes. Working modes Parts Counting and Percent Weighing
are exceptions.
8.4. WEIGHING UNIT SELECTION
Change of weighing unit is carried out by pressing the weighing unit icon visible next to the value of
measurement result, or by clicking key (if displayed in an information section). Clicking the unit
triggers its replacement, the clicked unit is replaced with the unit that is next on the list of available
units.
Another option for unit replacement is selecting a particular unit out of the units list, to view the list
click key (if displayed in an information section).
Units list:
Unit
Denotation
Verified balance
gram [g] yes
milligram [mg] yes *