Chapter 2 Command System RIGOL
DS1000Z Programming Guide 2-47
:MASK:SOURce
Syntax :MASK:SOURce <source>
:MASK:SOURce?
Description
Set or query the source of the pass/fail test.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
CHANnel1
Explanation Only the channel enabled can be selected as the source. You can sent
the :CHANnel<n>:DISPlay command to enable the desired channel.
Return
Format
The query returnsCHAN1, CHAN2, CHAN3 or CHAN4.
Example
:MASK:SOURce CHANnel2
Related
Command
:CHANnel<n>:DISPlay
:MASK:OPERate
Syntax :MASK:OPERate <oper>
:MASK:OPERate?
Description
Run or stop the pass/fail test, or query the status of the pass/fail test.
Parameter
Name
Type
Range
Default
<oper>
Discrete
{RUN|STOP}
STOP
Explanation Before executing this command, you need to send the :MASK:ENABle command to enable
the pass/fail test.
Return
Format
The query returns RUN or STOP.
Example
:MASK:OPERate RUN
Related
Command
:MASK:ENABle

Table of Contents

Other manuals for Rigol DS1000Z Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS1000Z Series and is the answer not in the manual?

Rigol DS1000Z Series Specifications

General IconGeneral
BrandRigol
ModelDS1000Z Series
CategoryTest Equipment
LanguageEnglish

Related product manuals