Chapter 2 Command System RIGOL
DS1000Z Programming Guide 2-55
:MEASure:CLEar
Clear one or all of the last five measurement items enabled.
Parameter
{ITEM1|ITEM2|ITEM3|ITEM4|ITEM5|ALL}
Explanation You can use the :MEASure:ITEM command to enable the desired parameters of the
24 waveform parameters. Note that the last five parameters are determined
according to the order in which you turned them on and they will not change as you
delete one or more measurement items.
You can send the
:MEASure:RECover command to recover the item which has been
Related
Commands
:MEASure:RECover
:MEASure:RECover
Recover the measurement item which has been cleared.
Parameter
{ITEM1|ITEM2|ITEM3|ITEM4|ITEM5|ALL}
Explanation You can use the :MEASure:ITEM command to enable the desired parameters of the
24 waveform parameters. Note that the last five parameters are determined
according to the order in which you turned them on and they will not change as you
delete one or more measurement items.
You can send the
:MEASure:CLEar command to clear the items again after one or all
of the measurement items are recovered.
Related
Commands
:MEASure:CLEar
:MEASure:ITEM