Engineering manual - SAB 193-233-283 S A-frame (including ATEX)
94/175
008831 en 2022.02
Technical data
6.4 Minimum compressor flow at 3550 rpm
The minimum flow capacity for each compressor varies depending on its geometry and its op-
erating conditions. Typical minimum flow for each of our compressor models is listed below.
Table 22 represents minimum suction flow with the slide valve fully unloaded.
Unit
Minimum flow*
CFM m
3
/h
SAB 193 S 71 121
SAB 193 L 95 161
SAB 233 S 125 212
SAB 233 L 157 267
SAB 233 E 365 621
SAB 283 S 224 380
SAB 283 L 282 479
SAB 283 E 650 1104
SAB 283 X 478 812
Table 22: Minimum suction flow
* at 3550 rpm