III - 36
Service Procedures
SM830063
3
1. Troubleshooting
(J) Change the period of the filter timer
If the period of filter timer is not suitable (for example in case of dirty environment), the period can be short-
ened to half as follows:
a Press the TEST / CHK button for more than 4 seconds.
e Press the SET button.
CODE No. 06, SET DATA and
SETTING
change from flashing to ON state.
f If you make mistake, press the CL button.
g Finally, press the TEST / CHK button.
b In case of group control, if you want to change all units in group control collectively, proceed next step remaining
“ALL” displayed.
If you want to change a unit individually, select the indoor unit address (UNIT No.) with UNIT button.
c Select the CODE No. 02 with
, (SET TEMP) button.
d Change the No. from 0 to 1 with
, ( ) button.
EX:
UNIT No. 1–6
CODE No. 02
X, S, T, SL type 2,500 hr
1,250 hr
AS, K, F, FM type 150 hr
75 hr
{
SET CL
MODE
FAN SPEED
ON
OFF
SET TEMP.
UNIT
FLAP
AIR FLOW
R.C. No.
SET
UNIT No.
No.CODE
TIMER SET
DATA
SETTING
TEST / CHK
0213_M_I
SET CL
MODE
FAN SPEED
ON
OFF
SET TEMP.
UNIT
FLAP
AIR FLOW
R.C. No.
SET
UNIT No.
No.CODE
SET TEMP.
TIMER SET
DATA
SETTING
TEST / CHK
0214_M_
I