PN-L803C/80TC3 SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 44
21. SENSOR CHECK TOOL
21-1. OPERATING CONDITIONS OF SENSOR CHECK TOOL
The operating conditions of the sensor check tool of the information display are as follows.
OS (32bit/64bit)
- Windows 8/8.1
- Windows 7
- Windows Vista
- .NET Framework 4.5 must be prepared.
Communication port - USB
21-2. START SENSOR CHECK TOOL
Click “Sensor Check” button on the Service Tool. The following screen is displayed.
“Check” and “View” buttons are activated only when
found
is displayed.
21-3. HOW TO USE SENSOR CHECK TOOL
Sensor Check (Open/Shortcircuit)
This check is to use whether the touching trouble is caused by the sensor or not.
1) Connect the PC with Service tool and the monitor by the video output cable and the USB cable. The two cables must be connected to
the same side of the monitor.
2) Turn on the main power of the monitor.
3) Check that the button next to “PN-L803C series” turns to
found
.
<CAUTION>
- When the button turns to
not found
even if one monitor is connected, there could be a problem in the route of the USB cable.
Check the harnesses and the PWBs of the USB cable route.
- When the button turns to
many
, this tool performs the checking one by one. Connect one target monitor to check and
perform the sensor check.

Table of Contents

Other manuals for Sharp PN-80TC3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp PN-80TC3 and is the answer not in the manual?

Sharp PN-80TC3 Specifications

General IconGeneral
BrandSharp
ModelPN-80TC3
CategoryMonitor
LanguageEnglish

Related product manuals