Additional information on SMS
B.5 Reply SMS message to the "MONITOR?" command
LOGO! CMR2020, LOGO! CMR2040
170 Operating Instructions, 10/2016, C79000-G8976-C356-03
Changing the phone number of a user
Function Changing the phone number of a user uniquely specified by the user name.
For the selected use
r, in the WBM in Users / groups in the User tab the corresponding release must
be entered see section User (Page 104).
Access Writing, password (when configured), right must be configured in the WBM
Structure and key-
word
<Password>;CHANGEUSER="User name","phone number"
With this command use the User name you need to enter when logging in to the WBM.
Return values
OK (optional) or error message: SMS error messages (Page 165)
Example Send SMS message: Password;CHANGEUSER="Joe","01751234567"
Reply SMS message: CHANGEUSER=Joe01751234567:OK
Querying the mobile wireless provider about the service code
Function Querying a service code with the mobile wireless provider, e.g. "*100#".
The text transferred by the mobile wireless provider is returned unchanged as the reply in an SMS
message.
If you use a prepaid SIM card, and want to query the current credit, the service can be used to que-
ry your credit. You cannot, however, use all possible service codes for queries.
Access
Writing, password (when configured)
Structure and key-
word
<password>;SERVICECODE="code"
Return values
Original reply of the mobile wireless provider or error message
Example Send SMS message: Password;SERVICECODE="*100#"
Reply SMS message: *100# Original text of the mobile wireless provider or error message
B.5
Reply SMS message to the "MONITOR?" command
Process image
The process image shows the current statuses and values of the CMR and the BM with its
expansion modules.
The number of I/O elements actually in the system depends on the expansion modules being
used.
SMS header
Value blocks
Module name of the CMR From: logo.cmr
Date and time of the module
<YYYY-MM-DD> <hh:mm:ss>
CMR
Value blocks
Digital inputs Inputs I1, I2
Digital outputs
Outputs
Q1, Q2

Table of Contents