Service cases - hardware
4.16 Terminal Modules
Hardware and Software
198 Service Manual, 03/2011, 6FC5397-5DP40-0BA0
4.16.2 TM54F connections
Connections
'5,9(&/L4LQWHUIDFHV
(OHFWURQLFVSRZHUVXSSO\
3URWHFWLYHFRQGXFWRU
FRQQHFWLRQ
01P
/('
6HQVRUSRZHUVXSSO\
6KLHOGFRQQHFWLRQ
)DLOVDIHGLJLWDOLQSXWV
SRZHUVXSSO\G\QDPL]DEOH
)DLOVDIHGLJLWDORXWSXW
)DLOVDIHGLJLWDORXWSXW
3RZHUVXSSO\
)RUGLJLWDORXWSXWV
)RUVHQVRUSRZHUVXSSO\
)DLOVDIHGLJLWDOLQSXWV
)DLOVDIHGLJLWDOLQSXWV
SRZHUVXSSO\G\QDPL]DEOH
)DLOVDIHGLJLWDOLQSXWV
)DLOVDIHGLJLWDORXWSXW
)DLOVDIHGLJLWDORXWSXW
;
;
;
;
;
;
;
;
;
;
;
;
;
Figure 4-47 TM54F connections
4.16.3 This is how you remove an TM54F
Overview
The activities that must be taken into account when replacing an TM54F are subsequently
described.
If a TM54F has a hardware defect, then it must be replaced by an identical module.
Preconditions:
● The module is defective and must be replaced.
● The control cabinet is in a no-voltage condition, all of the connectors and cables are
labeled.