Service cases - hardware
4.1 PPU 24x.2/26x.2/28x.2
Hardware and Software
74 Service Manual, 03/2011, 6FC5397-5DP40-0BA0
4.1 PPU 24x.2/26x.2/28x.2
4.1.1 PPU status displays
Status displays front side
On the front side of the PPU, the following status displays provide information about the
module state:
5'<
1&
&)
/LQN
$FWLYLWL\
Figure 4-2 Vertical flap (detail)
The three LEDs located behind the protective flap on the front side of the PPU have the
following significance:
Name Color State Meaning
Green Is lit NC Ready and PLC in run mode.
Yellow Is lit PLC in stop mode
Flashing Booting
RDY
Red Is lit NC in stop mode:
When booting, if NC Ready is not yet available
Critical fault (power off/on necessary)
NC Yellow Cyclic flashing NC operation
CF Yellow Is lit User CompactFlash Card being accessed
CAUTION
If the LED is lit, the CompactFlash Card must not be removed!
Non-compliance can result in damage to the CompactFlash Card.

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 828D
CategoryControl Systems
LanguageEnglish

Related product manuals