EasyManuals Logo
Home>socomec>Switch>ATyS s

socomec ATyS s User Manual

socomec ATyS s
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image

EN
ATYSp - 542001E - SOCOMEC
7.2.2. Meteringandsensingdetails
Network type
        
Source
1
1 phase
2 wire
2 phase
2 wire
2 phase
3 wire
3 phase
3 wire
3 phase
3 wire
3 phase
4 wire
3 phase
4 wire
3 phase
4 wire
3 phase
4 wire
Source
2
1 phase
2 wire
3x1 phase
4 wire
Source
1
1
N
2
3
1
N
2
1
3
2
1
3
2
1
32
N
1
32
N
1
32
N
1
32
N
Source
2
1
N
2
3
1
N
2
1
3
2
1
3
2
1
32
N
1
32
N
1
N
1
N
ATySp CT
cabling
(load side)
1
N
R1
R2
2
3
S1
S2
1
N
3
R1
S2
S1
R2
1
3
2
R2
R1
1
3
2
R2
S1
T1
T2
S2
R1
1
R1
R2
32
N
1
R1
S2
T2
T1
S1
R2
32
N
1
R1
S2
T2
T1
S1
R2
32
N
1
R1
S2
T2
T1
S1
R2
32
N
Voltage sensing
Source
1
-
V1
U23 U12
V1, V2
U12, U23, U31 U12, U23, U31 U12, U23, U31
V1, V2, V3
U12, U23, U31
V1, V2, V3
U12, U23, U31
V1, V2, V3
U12, U23, U31
V1, V2, V3
Source
2
-
V1
U23
-
U12
V1, V2
U12, U23, U31
-
U12, U23, U31
-
U12, U23, U31
V1, V2, V3
U12, U23, U31
V1, V2, V3
-
V1
-
V1, V2, V3
Source
presence
(source
available)
3 3 3 3 3 3 3 3 3
Source
in ranges
(U,V,F)
3 3 3 3 3 3 3 3 3
Rotation
phase
order
- - -
3 3 3 3
S1 only S1 only
Neutral
position
- -
3
- -
3 3
S1 only S1 only
Voltage
unbalanced
is lower
than
threshold
- - -
3 3 3 3
S1 only S1 only
Metering applicable to ATySp
Source
1
-
V1
f1
U23
-
f1
U12
V1, V2
f1
U12, U23, U31
-
f1
U12, U23, U31
-
f1
U12, U23, U31
V1, V2, V3
f1
U12, U23, U31
V1, V2, V3
f1
U12, U23, U31
V1, V2, V3
f1
U12, U23, U31
V1
f1
Source
2
-
V1
f2
U23
-
f2
U12
V1, V2
f2
U12, U23 ,U31
-
f2
U12, U23, U31
-
f2
U12, U23, U31
V1, V2, V3
f2
U12, U23, U31
V1, V2, V3
f2
-
V1
f2
-
3xV1
f2
If CT
connected
(load side)
-
-
-
P
T
, Q
T
, S
T
, PF
T
-
-
-
P
T
, Q
T
, S
T
, PF
T
P1, Q1, S1, PF1
P2, Q2, S2, PF2
-
P
T
, Q
T
, S
T
, PF
T
I1, I2
-
-
-
P
T
, Q
T
, S
T
, PF
T
I1, I2, I3
P1, Q1, S1, PF1
P2, Q2, S2, PF2
P3, Q3, S3, PF3
P
T
, Q
T
, S
T
, PF
T
I1, I2, I3, In
-
-
-
P
T
, Q
T
, S
T
, PF
T
I1, I2, I3
P1, Q1, S1, PF1
P2, Q2, S2, PF2
P3, Q3, S3, PF3
P
T
, Q
T
, S
T
, PF
T
I1, I2, I3, In
P1, Q1, S1, PF1*
P2, Q2, S2, PF2
P3, Q3, S3, PF3
P
T
, Q
T
, S
T
, PF
T
I1, I2, I3, In
P1, Q1, S1, PF1*
P2, Q2, S2, PF2
P3, Q3, S3, PF3
P
T
, Q
T
, S
T
, PF
T
I1, I2, I3, In
* Values, only visible on Source
2

Table of Contents

Other manuals for socomec ATyS s

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the socomec ATyS s and is the answer not in the manual?

socomec ATyS s Specifications

General IconGeneral
Brandsocomec
ModelATyS s
CategorySwitch
LanguageEnglish

Related product manuals